Basic Info.

Model NO.
TAK006
Insulating Medium
Epoxy Resin
Installation
PCB Mounting
Magnetic Circuit Structure
Combined Type
Voltage Transformation Principle
Electromagnetic Type
Transport Package
Carton
Specification
38.5*22*22cm
Trademark
Bingzi
Origin
China
HS Code
8504311000
Production Capacity
10000000per Year

Product Description


1. Features:
Compact in size with high load capacity; open-close design, easy to install and use, widely applied in power operation, maintenance and reconstruction projects. 

2. Ambient Conditions:
 Operating temperature: -20ºC ~ +50ºC;
 Relative humidity: ≤90% at 40°C;
 Atmospheric pressure: 860 ~ 1060 mbar (about 650 ~ 800 mmHg).

3. Operating Frequency Range: 50Hz~1kHz

4. Insulation Thermal Class: Class B (130ºC)
 
5. Safety Features:
 Insulation resistance: >100MΩ in normal condition;
 Insulation withstand voltages: 1KV 50Hz/1 min;
 Fire retardancy: In conformity with UL94-V0 ;
 Mechanical strength: opening and closing times ≥ 1000 times.
 
6. Outline Drawing, Installation Dimension and Coil Diagram: (Tolerance ± 0.5mm)  

TAK006 Series Split Core AC Current Transformer
    TAK006 Series Split Core AC Current Transformer                                                   
                                                 

7. Typical Applications and Performance Parameters:

See the table below for performance parameters when applied as shown in Figure 3.
TAK006 Series Split Core AC Current Transformer 
Model Rated
Input Current
Rated
Output Current
Rated
Sampling Resistance
(RL )
Rated
Sampling Voltage
Non-linearity Linear Range
TAK006-01 1A 1 mA 10Ω 10mV 2% 1.2 times of the rated value
TAK006-02 2A 2.5mA 20mV 2% 1.2 times of the rated value
TAK006-03 5A 5mA 10Ω 50mV 2% 1.2 times of the rated value
TAK006-04 10A 10mA 50mV 2% 1.2 times of the rated value
TAK006-05 20A 25mA 125mV 2% 1.2 times of the rated value
 
8.Attention:
 Connect the primary winding of the current transformer in series with the loop of the measured current. Operate the secondary winding in a near short-circuit mode.
 Do not allow the secondary circuit of the current transformer to be open-circuited. Do not connect any fuse in the secondary loop.















 

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now

You Might Also Like

Gold Member Since 2024

Suppliers with verified business licenses

Manufacturer/Factory, Trading Company, Group Corporation
Registered Capital
47686000 RMB
Plant Area
>2000 square meters