Type: | Fluxgate Type |
---|---|
Output Signal Type: | Analog Output |
Production Process: | Integration |
Material: | Plastic |
Accuracy Grade: | 0.1G |
Application: | Switching Power Supply |
Suppliers with verified business licenses
Parameter | Symbol | Unit | Specification | Conditions |
To load Over-voltage | VC | V | 32 | 400 ms |
Over-voltage | VC | V | 24 | 10 minutes |
Reverse input voltage | VC | V | -50 | 10 minutes |
Minimum input voltage | VCmin | V | 6 | Continuous, not measuring |
Maximum input voltage | VCmax | V | 18 | Continuous, not measuring |
CAN work, low voltage fault alarm, non-measurement | VC | V | 6~7 | CAN continuous |
CAN work, Over-voltage fault alarm, non-measurement | VC | V | 18~24 | CAN continuous |
Creepage distance | dcp | Mm | 7.2 | |
Clearance | dCI | Mm | 7.0 | |
RMS voltage for AC insulation test | Vd | KV | 2.5 | 50 Hz, 1 min |
Voltage for DC insulation test | Vd | KV | 5.0 | |
Insulation resistance | RINS | MΩ | 500 | 500V@ 1min |
IP level | IP42 | 1 min |
Parameter | Symbol | Unit | Specification | Conditions | |||
Min. | Typ. | Max. | |||||
Primary current measurement range | IPN | A | -500 | 500 | |||
Supply voltage | UC | V | 7 | 12 | 18 | full precision | |
Maximum voltage hysteresis | Uup | V | 18.1 | when Uc rises | |||
V | 17.7 | when Uc falls | |||||
Minimum voltage hysteresis | ULOW | V | 7.1 | when Uc rises | |||
V | 6.8 | when Uc falls | |||||
Current consumption@Ip=0A | IC | mA | 20 | 30 | @ VC= 12.0V, CAN work normally | ||
Current consumption@Ip=500A | IC | mA | 150 | 200 | @VC= 12.0 V, CAN work normally | ||
Working temperature | TA | ºC | -40 | 85 | temperature range, accuracy guaranteed to ±3 δ | ||
Total accuracy | XG | % | -0.5 | 0.5 | T = -40 ~ 85ºC ; ± 3δ | ||
Regional error | IP=± 6A | XG | V | -0.2A | 0.2A | T = -40 ~ 85ºC | |
IP=± 80A | XG | V | -0.5A | 0.5A | |||
IP=±350A | XG | V | -1.75A | 1.75A | |||
IP=±500A | XG | V | -2.5A | 2.5A | |||
Linearity | εL | % | 0.1 | at room temperature | |||
Gain temperature drift | TCG | ppm/ºC | 20 |
Message Description |
CAN ID | Name | Data length (Nb bytes) |
Type of frame | Send cycle | Information description | Signal name | Start bit | End bit |
Primary current IP (mA) |
See the product model list for details | CS09H - 500Ip | 8 | standard frame | 10ms loop sending | Ip current value: 80000000H=0mA, 7FFFFFFFH=-1mA, 8000001H=1mA | IPVALUE | 0 | 31 |
Fault identification bit (0=normal, 1=fault) | ERROR INDICATION |
32 | 32 | ||||||
Fault information (when the fault flag is 0, it is 0x64) | ERROR INFORMATION | 33 | 39 | ||||||
Fixed at 0x48 0x11 | SENSORNAME | 40 | 55 | ||||||
Software version | SWRevision | 56 | 63 |
SN | Failure mode | IP value | Fault flag | Error code |
1 | CRC check error failure | 0x FFFFFFFF | 1 | 0x40 |
2 | A FE overload fault | 0x FFFFFFFF | 1 | 0x41 |
3 | A FE error failure | 0x FFFFFFFF | 1 | 0x42 |
4 | Internal LUT failure | 0x FFFFFFFF | 1 | 0x44 |
5 | Power supply undervoltage fault | 0x FFFFFFFF | 1 | 0x46 |
6 | Power supply Over-voltage fault | 0x FFFFFFFF | 1 | 0x47 |
SN | Product number | CAN ID | CAN Communication baud rate (kbps) |
1 | CS09H-500A-C20 | 0x03C0 | 250 |
2 | CS09H-500A-C21 | 0x03C1 | 250 |
3 | CS09H-500A-C22 | 0x03C2 | 250 |
4 | CS09H-500A-C23 | 0x03C3 | 250 |
5 | CS09H-500A-C24 | 0x03C4 | 250 |
6 | CS09H-500A-C25 | 0x03C5 | 250 |
7 | CS09H-500A-C26 | 0x03C6 | 250 |
8 | CS09H-500A-C27 | 0x03C7 | 250 |
9 | CS09H-500A-C28 | 0x03C8 | 250 |
10 | CS09H-500A-C29 | 0x03C9 | 250 |
11 | CS09H-500A-C50 | 0x03C0 | 500 |
12 | CS09H-500A-C51 | 0x03C1 | 500 |
13 | CS09H-500A-C52 | 0x03C2 | 500 |
14 | CS09H-500A-C53 | 0x03C3 | 500 |
15 | CS09H-500A-C54 | 0x03C4 | 500 |
16 | CS09H-500A-C55 | 0x03C5 | 500 |
17 | CS09H-500A-C56 | 0x03C6 | 500 |
18 | CS09H-500A-C57 | 0x03C7 | 500 |
19 | CS09H-500A-C58 | 0x03C8 | 500 |
20 | CS09H-500A-C59 | 0x03C9 | 500 |
Suppliers with verified business licenses