HV03F-10/25mA-P SERIES VOLTAGE TRANSDUCER/SENSOR
DESCRIPTION:
For the electronic measurement of current: DC, AC, pulsed ..., with galvanic separation between the primary and the secondary circuit.
FEATURES:
Closed loop using the Hall effect
The primary side and the secondary side are isolated
Low power consumption
Wide range
No insertion loss
Raw materials recognized according to UL 94-V0
APPLICATIONS:
Inverter
Uninterruptible Power Supplies (UPS)
Static converters for DC motor drives
Switched Mode Power Supplies (SMPS)
Welding machine power supply
Battery management
MODEL LIST:
Product model |
Model |
Rated input current IPN ( mA ) |
Rated input voltage VPN ( V ) |
Measuring range IPM ( mA) |
HV03F-10/25mA-P |
10 |
10~1500 |
0~ ± 14 |
HV03F-10/25mA-P SPECIFICATION
Parameter |
Symbol |
Unit |
Value |
Test Conditions |
Electrical Data |
Supply voltage (±5%) (1) |
VC |
V |
±15 |
|
Current consumption |
IC |
mA |
10+ output current |
|
Output current ISN |
ISN |
mA |
25 |
|
Overcurrent capability (1ms ) |
IPC |
At |
- |
|
Insulation resistance |
RIS |
MΩ |
> 2 0 00 |
@500VDC |
Internal impedance |
RS |
Ω |
117 |
approximation |
Load Resistor (2) |
RM |
Ω |
0~200 |
|
Performance Data |
Linearity (3) (0…± IPN ) |
εL |
%of IPN |
<±0.2% |
@TA = 25°C |
Precision |
X |
% |
<±0.8% |
@ IPN , TA = 25°C |
( remove zero offset current ) |
Zero offset current |
IOE |
mA |
<±0.15 |
@ IP= 0 , TA=25°C |
Magnetic offset current |
IOM |
mA |
<±0.1 |
@ IP = 0; |
1 times the rated current impact |
Zero offset temperature drift |
IOT |
mA |
<±0.5 |
@ IP =0 , @ -25 ~ +85 °C |
<±0.8 |
@ IP =0 , @ -40 ~ +85 °C |
Response time |
tr |
µS |
<25 |
@ 90% of IPN step response |
Current follows di /dt |
di/dt |
A/µS |
- |
|
Bandwidth (4) |
BW |
kHz |
DC~150 |
@-3dB |
General Data |
Working ambient temperature |
TA |
ºC |
-40….+85 |
|
Storage ambient temperature |
TS |
ºC |
-40….+100 |
|
Weight |
m |
g |
22 |
approximation |
Notice:
(1) Under the power supply condition of ±12V≤VC≤±15V, the measurement range of the sensor will be reduced;
(2) If the customer uses the rated load resistance, the current to be measured needs to be limited to the rated current. If the full-scale current is to be measured, the load resistance should be smaller than the rated resistance;
(3) Linearity data does not include zero offset.
Insulation data :
Parameter |
Symbol |
Unit |
Value |
Comment |
AC isolation withstand voltage test RMS @ 50Hz, 1min |
UD |
KV |
4.2 |
|
Impulse withstand voltage 1.2/50uS |
UW |
KV |
16 |
|
Shell material |
- |
- |
UL94-V0 |
PPO |
Relative tracking index |
CTI |
PLC |
175 |
|
Creepage distance |
dCP |
mm |
19.5 |
|
Electrical clearance |
dCI |
mm |
19.5 |
|
Maximum limit :
Parameter |
Symbol |
Unit |
Value |
Supply voltage |
VC |
V |
±18 |
Output current (output shorted to ground) |
Iout |
mA |
- |
Electrostatic discharge - contact discharge |
VESD |
V |
- |
Safety
This device must be used according to IEC610101.
This device must be used in electric/electronic equipment with respect to applicable standards and safety requirements in accordance with the operating instructions.
Caution, risk of electrical shock.
When operating the device, certain parts can carry hazardous voltage (eg. primary busbar, power supply). Ignoring this warning can lead to injury and/or cause serious damage.
This is a builtin device, whose conducting parts must be inaccessible after installation.
A protective housing or additional shield can be used.
Main supply must be able to be disconnected.